Architectural Design Manual
Revised by IN-LINE Architecture, upon instruction from
Belle Rio Estate Homeowners Association
(July 2024 Rev 01)
©
FLC van Schalkwyk
Table of Contents
1
2 3 4 5
5.1
5.2
5.3
6
6.1
6.2
7
7.1
8 9
9.1
9.2
9.3
10 11 12 13 14 15 16 17
Introduction General Information Architectural Planning Town Planning Requirements Building Envelope
Primary Structure
Secondary Structure
Linking Elements
Roofs
Roofs to Primary Buildings
Roofs to Secondary Structures
Linking Elements and Free-standing Structures
Building Platform
Retaining Structures
Parking, Garages and Carports Columns
Square Masonry without a Base
Square Masonry with a Base
CCA treated round poles
Boundary and Yard Walls Exterior Walls Windows Doors Awnings Gates Shutters Ventilators
1
18 19 20
21
22
23
24
25 25.1 25.2 25.3 25.4 25.5 25.6 25.7 25.8 25.9
Chimneys Balconies Balustrades
Pergolas
Lights
Security Systems
Driveways
Services Satellite Dishes and Television Aerials Service Pipes Telephone Air-Conditioning House Numbers and Names Post Boxes Gas Cylinders, Refuse Bins and Washing Lines Solar Heating Rainwater Storage Tanks
25.10 Swimming Pools
Irrigation Maintenance Exterior Colours
Walls
Doors, Windows, Shutters and Gates
Roofs
Fascia’s and Gutters
Landscaping Building Plan Approvals Building Operations Control
26 27 28
28.1
28.2
28.4
28.5
29 30 31
2
1
INTRODUCTION
The intention of these manual is to establish design rules that provide Architectural
Professionals with a framework within which to design buildings in a harmonious style
and of an integrated aesthetic standard. Although the proposed style of building is
sympathetic to the traditional Farmhouse architecture and takes cognisance of
historical elements of this style, the intention is to allow the buildings to blend in rather
than contrast with the environment. Building forms and materials are stipulated to
promote a sense of uniformity, but at the same time to allow a great variety of
spatial relationships to be developed within the community living context.
Although this manual excludes certain forms, materials and colours, they should not
be seen as a restrictive measure, but as an instrument to maintain an overall design
sensitivity, whilst still allowing enough flexibility for individual expression.
This manual is supplementary to the National Building Regulations and requirements
of the local Authority.
Owners and their architectural designers must present all building designs to the
Homeowners Association in two stages: a first submission (Sketch Plans) and final
submission (Local Authority Submission).
No building construction will be permitted unless the architectural design complies
with this manual and has been approved by the Belle Rio Estate Homeowners
Association or its nominated architectural professional prior to submission to the
Local Authority.
Procedures and requirements for plan submissions are set out at the end of this
document.
2
GENERAL INFORMATION
The Belle Rio Estate Homeowners Association (BREHOA) has appointed IN-LINE
Architecture as its Architectural Consultant. IN-LINE’s role will be to act on behalf of
the BREHOA in ensuring compliance with this manual, the approval of plans for all
building structures within the development.
IN-LINE’s offices are in Kakamas and contact details are as follows:
IN-LINE Architecture
2366 Neethling Street
Kakamas, 8870
P O Box 1166, Kakamas, 8870
Cell
: +27 (0)83 725 6996
E-mail: frik@inlinearch.co.za
A scrutiny fee is payable directly to the architects, before scrutiny of the plans. Such
fees are to be paid by the owner of an erf upon which construction is to take place.
3
All building designs and drawings for the construction of new houses as well as alterations and/or additions to houses must be prepared by architectural professional registered with the South African Council for the Architectural Profession (SACAP).
The submission of building plan is also required for:
Boundary walls, pergolas and any changes:
External finishes,
The design, type, style and sizes of all external doors, windows and gates and
Any external detail or design that may alter the elevation, aesthetics, style or
character.
The omission of any portion of the building, building item or element shown on the
approved plans or addition of any building item or element described in this
document, will also require the approval of building plans and/or other written
approval by BREHOA.
The BREHOA may amend this architectural design manual from time to time to clarify
issues or add provisions as they become necessary. Such amendments will not be
retroactive and will be at the sole discretion of the BREHOA. Where variations are
permitted with respect to specific conditions on a particular site, such variations will
not be considered as permanent amendments to the design manual.
Where the architectural design manual does not address a particular aspect of a
design proposal or a difference of opinion regarding interpretation arises; the
nominated architectural professional shall make a ruling, which will be binding, and
final. Future building alterations will also be subject to the architectural design
manual current at that time.
The nominated architectural professional may request any such changes in design
or site layout that, in their opinion, are required to preserve the planning,
architectural and environmental objectives of The Belle Rio Estate Owners
Association.
No deviation from the approved plans will be permitted during construction. Any
changes to the approved plans must be submitted to In-Line Architecture for
approval before implementation on site.
The Belle Rio Estate Owners Association reserves the right to enforce rectification of
any deviations from the approved building plans.
3
ARCHITECTURAL PLANNING
Aesthetic standards and compliance with the manual will be important
consideration when plans are scrutinised for approval. The Homeowners Association
may reject plans purely on the basis that it might consider them to be aesthetically
unacceptable.
Architects must make sure that all the local environmental conditions are
considered. (Prevailing wind, sun, rainfall, views, etc.)
Consideration must be given to ensure maximum level of privacy for owners as well
4
as their neighbors. Examples of existing work at Belle Rio Estate showing certain principals / details /
finishes ect. do not guarantee that it will automatically be approved again for inter
alia the following reasons:
Each design will be judged on its own merits,
Some of the work executed may be unauthorized,
A waiver may have been granted under special circumstances,
Further manual may have been established.
4
TOWN PLANNING REQUIREMENTS
Building Lines The building lines demarcate areas adjacent to the boundaries within which a
building or structure other than a boundary wall or yard wall may be erected.
Street boundary
Side boundary
Rear boundary
Boundary between Erf 2 and Erf 3 to Erf 41: 0.5m
Parking: at least two parking bays per house. Height Restriction Maximum height to ridge of roof (measured from average natural ground level):
: 0.5m for carports and garages.
: 5.0m for any inhabited space.
: 2.0m
: 2.0m
For single storey sites
For double storey sites : 10.5m
: 6.0m
(Erf 3 to Erf 41)
(Erf 42 – 68, 72-82 and 84 – 110)
If a building exceeds its height restriction, the owner will be fined by the Belle Rio
Estate Homeowners' Association and the owner may be forced to rectify the non-
compliance which may necessitate the demolition of the house.
5
BUILDING ENVELOPE
The building envelope may include a main dwelling structure (primary structure) with
secondary structure attachments formed by low pitched roofs, verandahs and
abutments. Secondary structures must have flat roofs. A garage may be detached
from the main building as an outbuilding.
Maximum coverage allowed per erf is:
50%.
60%
60%
for Erf 3 – 16, 37 – 68 and 96 – 110
for Erf 17 – 36, 72 – 82 and 84 – 95
for Erf 71 and 83
This ‘footprint’ includes all roofed areas and is calculated on the same basis as used
by the local authority when determining the coverage of a proposed building.
5
ARCHITECTURAL PRINCIPLES:
FORM & SPACE Plan forms should be composed of simple geometrical rectangular and/or square
forms. The basic form of the house must result from the addition of simple, distinctive
and clearly articulated rectangular and/or square “boxes” This principle must be
applied in all aspects and dimensions of the architectural design and must be
clearly legible.
The built form should also be fragmented, avoiding too heavily massed built form.
This fragmentation can be achieved by means of combining simple geometrical
form into a single built form.
ORDER & CONNECTIONS Building forms should be composed of main and secondary-plan elements
connected by smaller connecting forms e.g. Lean-to roofs connected via smaller
flat roofs.
The primary building elements should be arranged in an architectural order.
Haphazardly arranged geometrical shapes will not be allowed.
Where a flat concrete roof is used as a connecting element between two major
forms, the top of the concrete parapet must be at least 340mm below the roof
overhang of the major roof elements.
PROPORTION & SCALE Careful consideration shall be given to the scale proportion and articulation of
building forms, as these, together with the use of stonework, chimneys, openings in
walls, etc. are very important to create a cohesive architectural character. The
architecture should be seen as an additive one where a series of major plan form
elements are connected by minor plan form elements rather than a monolithic
sculptured architecture.
The building elements should be related to each other in proportion and scale. All
components should be relatively in the same proportions to each other. Proportions
will have to be clearly defined and legible.
ARTICULATION Platonic forms and shapes should be articulated by means of additive
transformation.
Uninterrupted, visually heavy, unarticulated and massive forms will be prohibited,
whether in compliance with design manual or not. The edges and connections of
the forms should be clearly legible and articulated.
6
5.1
PRIMARY STRUCTURE
Primary structures shall have a single rectangular form or a simple combination of
rectangular forms, perpendicular to each other, of which the length must be at least
twice the width of the structure.
Primary structures must have double-pitched roofs, ended in gables.
Long continuous flat facades are discouraged, and the plan form must be
articulated.
Rectangular primary structures must be parallel to the site boundaries.
Hipped roof junctions at 90° angles are not allowed.
5.2
SECONDARY STRUCTURES
Secondary structures must be perpendicular to the primary building. Secondary structures must be 340mm lower than the adjoining roof overhang. No curved secondary structures and freestanding structures are allowed.
5.3
LINKING ELEMENTS
Two or more primary structures with separate roofs may be connected with a linking
element. This linking element must have a flat roof (5° or less).
A concrete flat roof may be used as a linking element between major plan forms.
The parapet of these slabs may not be above the eaves or facias of the adjoining
plan forms. Concrete roofed elements should be utilized at level changes between
major plan form elements.
Where a flat concrete roof is used as a connecting element between two major
forms, the top of the concrete parapet must be at least 340mm lower than the
adjoining roof overhang of the major roof elements.
The extent of flat roofs as linking elements will be restricted to a width of 5.0m and be
contained, on two sides at least, by major forms and should not project more than
3.0m beyond the extent of the major form.
6 6.1
ROOFS ROOFS TO PRIMARY BUILDINGS
Only double-pitched roofs of 30°, symmetrical at the gable ends are permitted on
primary buildings.
Eaves of double-pitched roofs must be 600mm.
Verandas or lean-to roofs may be used to extend the cover.
7
Parapets to gable walls shall follow the roofline with a height of 230mm measured parallel from the roof finish to the top of the finished parapet wall.
Gables must be at the same pitch as the roof in a simple triangular form without
curves and horizontal stepped parapets at the eaves.
Hipped roofs or hipped roof junctions at 90° angles are not allowed. Roofs must end
in gables.
6.2
ROOFS TO SECONDARY STRUCTURES, LINKING ELEMENTS AND FREE-STANDING
STRUCTURES
Only flat roofs will be allowed on secondary structures and linking elements
structures.
Flat roofs for secondary structures are defined as roofs with a pitch of 5°. The extent
of the secondary flat roofs will be no greater than 50% of the total roofed area. Such
roof structures must have finished parapet walls on at least two sides.
Flat roofs for linking elements are defined as reinforced concrete roofs slabs. The
extent of the flat concrete roofs will be no greater than 30% of the total roofed area.
Concrete roofs must have parapet walls, 170mm high on all visible sides.
Freestanding buildings must have a flat roof with a pitch of 5˚, with parapets on
three sides. Parapets shall follow the roofline with a height of 230mm measured
parallel from the roof finish to the top of the finished parapet wall.
Roofing material
●
Corrugated, Victorian S profile Zincalume or Colorbond metal roof sheeting.
Colours allowed:
o Zincalume
African White / Amazing White
Cape White / Cedarberg White
Shale Grey / Ultimate White
Dune / Sahara Sand
o Colorbond
Fish Eagle White
White Lion
Sandstone Beige
Dove Grey
Gemsbok Sand
●
Reinforced concrete roof slabs with waterproofing and 19mm crusher stone
finish on top.
Skylights may be used on roof structures:
Flat roofs - These skylights may not project higher than the parapet that
surrounds them in elevation.
Pitch roofs – Tubular Skylight only
8
7
BUILDING PLATFORM
Buildings designed on slopes must respond to the slope with stepped levels /
buildings platforms.
The height of ground fill may not be higher than 340mm measured from the natural
ground level where the fill is to occur.
Where a building is designed to cut into the ground at the higher part of the site, this
cut may not be deeper than 510mm measured from the natural ground level where
the cut is to occur.
If a plinth is employed it may not exceed 510mm in height. This rule also applies to terracing in the landscaping around a house.
7.1
Retaining Structures
Retaining structures must be solidly built cement plastered walls or natural stonewalls. No pre-cast concrete engineering blocks (Terraforce, Loffelstein or similar) are
allowed.
8
PARKING, GARAGES AND CARPORTS
Each erf must be provided with off street parking for two vehicles, inclusive of the
parking inside a garage. Only garage doors with horizontal pattern must be installed.
No ornate panelled garage doors are allowed.
A maximum of two visible garage doors is permitted on one property. Freestanding garages must have flat roofs with parapets on three sides and conform
to provisions defined under “Roofs”.
9
COLUMNS
Columns to verandas and pergolas may comprise the following:
9.1
(A)
Square masonry columns without a base
These columns must be square 345 x 345mm brickwork columns without a
base. Columns to be constructed of brickwork and finished to match the
main building wall finish.
9.2
(B)
Square columns with a base
These columns must be square 100 x 100mm square tube / 230 x 230mm
brickwork columns with a 345 x 345mm base; the height the base may not
exceed 700mm in height. The base must be cladded with natural stone.
9
9.3
(C)
CCA treated round poles
Wooden structures (pergolas) may be supported by min. 150mm diameter CCA treated round poles. Timber shall be left natural or painted white.
No copies of Greek or Roman columns are permitted. Columns may not be fluted.
The top of the column must be simple and not ornate.
No Victorian cast iron or “broekie lace” details are permissible.
10
BOUNDARY AND YARD WALLS
Boundary walls Boundary walls and walls not build on an actual boundary line, but which fulfil the
function of a boundary wall in relation to a boundary, will be deemed to be
boundary walls. These walls may not exceed,
o 650mm in height for the street boundary,
o 650mm in height for first 5.0m of the side boundary from the street boundary,
o 1200mm in height for side and back boundary.
Drying yards
o to be screened from neighbouring properties and any street view,
o must be 1800mm high brick walls. The height of the screened yard wall will be
measured from ground floor, floor level minus 85mm,
o Must be finished to match the main building wall finish and
o may only constitute 10% of the coverage of the residence.
Boundary and drying yard walls must be brick walls minimum 230mm wide plaster
and painted to match main building wall finish.
Street boundary walls can be cladded on all sides and top with natural stone.
No columns may be incorporate in the boundary or drying yard walls. No recesses or raised panels, or any other embellishment may be incorporated in a
wall.
Palisade fencing, wire mesh fencing, timber or precast walls and any other type of
fencing are not permitted.
11
EXTERIOR WALLS
All external walls shall be 230mm thick brick walls plastered and painted.
The selective use of natural stone finishes is encouraged for example:
o
Selected recessed natural stone panels,
o Linking elements and
o Smaller secondary structures.
Plaster bands are encouraged, maximum width 120mm.
10
12
WINDOWS
Windows must have square or vertical rectangular proportions. Windows in a
structure must be of similar proportion.
Windows between veranda roofs and primary structure roofs are encouraged
(Clerestory windows). The rule of less is more will apply.
Burglar bars inside should be of horizontal form. Window frame color: Bronze or White. NOT ALLOWED:
Off-centre gable windows,
Winblock or other pre-cast concrete windows, glass block windows, or leaded
windows with diamond or other patterns,
Bay windows,
Dormer windows,
Cottage pane windows,
No external burglar bars,
Coloured glass and “mirrored” glass are not permissible in windows or doors.
13
DOORS
Door openings shall have vertical proportions. Doors onto verandas and covered
stoeps may be used in series and may be continuous behind a veranda or pergola.
14
AWNINGS
No awnings are permitted, whether fixed, retractable or adjustable. Verandas and
pergolas should be utilized to create shade. However, if shading is required as per
SANS 10400XA details of shading must be submitted for approval.
15
GATES
Only horizontal patterned gates are permitted. Gates should only be used at service yards or at streets as pedestrian access to a
property.
Colour : To match window colour.
16
SHUTTERS
Shutters must be functional. No false shutters are allowed. Shutters must be epoxy coated aluminium.
11
The colour of window or door shutters must match the window and door colours.
17
VENTILATORS
Ventilator louvers on gables are not allowed.
18
CHIMNEYS
Chimneys must be cladded with natural stone. The highest point of a chimney must be min. 1000mm above the roof on which (or
adjacent to which) it is built.
The height of the base may be adjusted to achieve proportions that are
aesthetically pleasing.
19
BALCONIES
Balconies must be well integrated into the design of the house and may not be
positioned in such a way that they are intrusive to neighbours, or compromise
privacy.
20
BALUSTRADING
All external balustrades must be shown on the drawings with the material and finish
specified.
21
PERGOLAS
Pergolas used as screening elements and as carports are allowed.
Paragraphs 22 to 30 will be applicable to the exclusive discretion of the Owners Association and is not subject to the powers of the Kai! Garib
Municipality.
22
LIGHTS
Lights on walls at the entrance door and garage play an aesthetic and functional
role and offer a warm welcome for visitors.
No external pole mounted street-type lamps on free–standing poles or bollards are
permitted.
All external light sources should be screened by solid flange structure louvers.
No coloured bulbs or glass to light fittings is permitted.
12
Lights on verandas must be low intensity and concealed. Down lighters are preferred.
No Spotlights or Floodlights are allowed.
23
SECURITY SYSTEMS
Burglar Bars, security screens, gates and expanding/sliding products, as well as roller
shutter systems, must be mounted on the inside of doors and windows.
24
DRIVEWAYS
All driveways and parking bays must be constructed with a hard surface using
approved paving.
25
SERVICES
25.1
SATELLITE DISHES AND TELEVISION AERIALS
These must be fitted on a primary building below the eaves line and may not be
fixed to a gable.
25.2
SERVICE PIPES
Sewer vent pipes, all drainage pipes, water pipes, air–condition trucking and
condensate pipes must be concealed in vertical ducts within the confines of the
building envelope.
25.3
TELEPHONE
Wires and cables must be laid underground. No overhead masts or wires will be
permitted. Amateur radio (ham) equipment and masts are also not permitted.
25.4
AIR - CONDITIONING
Air conditioner condensers must be positioned in a service yard or alternatively
installed against exterior walls at ground level with the top of the equipment not
higher than 1200mm above ground level.
Only wall type or ceiling type units are allowed. Window mounted units are not
permitted,
13
25.5
HOUSE NUMBERS AND NAMES
House numbers and names must not be longer than 75mm high and 60mm wide per
individual letter or number.
25.6
POST BOXES
No freestanding post boxes are permitted.
25.7
GAS CYLINDERS, REFUSE BINS AND WASHING LINES
These items must all be located within service yards.
25.8
SOLAR HEATING
Only separate tank and solar panels must be used for solar heated hot water
systems. Combined tank and panel systems are not allowed on a roof. The panels
are to be fixed on the roof of a primary building or secondary structure only.
Remote equipment must be in a service yard.
25.9
RAINWATER STORAGE TANKS
Rainwater storage tanks are allowed but not encouraged.
25.10 SWIMMING POOLS
25.10.1
25.10.2
25.10.3
25.10.4
25.10.5
At least 75% of a swimming pool plan area must be below ground
level.
Pools may have a rim-flow feature, integrated into the design of the
pool. The top of the rim-flow edge may not be higher than 300mm
above natural ground level.
Owners are mandated to control access to swimming pools in
accordance with the Nasional Building Regulations.
Swimming pool pumps must be carefully positioned so they are not
visible from public areas or neighbouring properties or create a noise
disturbance to neighbours. Pump must be screened with a wall that
matches the colour and finish of the main dwelling.
During backwash, rinse cycles and when being drained, the
chlorinated water effluent from a swimming pool must be pumped into
a stormwater sump on site and may not be discharged into the
landscape.
14
25.10.6
Pool decks may not be higher than 300mm above natural ground level.
26
IRRIGATION
Irrigation must be designed in such a manner as not to stain walls and structures on a
property.
27
MAINTENANCE
If gardens are cultivated, they are to be always kept tidy.
28 28.1
EXTERIOR COLOURS WALLS Light earthy colours for approval. Plaster bands - earthy Pastel colours two tints lighter than walls.
28.2
WINDOWS, DOORS, SHUTTERS AND GATES Bronze or White
28.3
ROOFS
See roofs
28.4
FASCIA’S AND GUTTERS Fascia’s – to match plaster bands. Gutters and downpipes are not encouraged – to match plaster bands.
29
LANDSCAPING
No declared invasive alien plants, trees, shrubs and grasses are permitted on
properties and may not be cultivated.
No extension of gardens into an immediately adjacent open space or pavement
areas will be permitted. On pavements only lawn grass well maintained will be
permitted.
15
No temporary structures are permitted on any property, including Wendy houses. The objective of the small allowable gardens is to contribute to the natural habitat. Hard landscaping surfaces (brick and other paving, tiling, etc.) will only be permitted
where it is functional for driveways, service yards, and footpaths to front doors, braai
areas, pool surrounds and verandas.
Extravagant use of hard landscaping will not be permitted.
30
BUILDING PLAN APPROVALS
Preamble One of the keystones of value in the development is the Architectural Guideline
which is a legal document to ensure that the integrity of the development is not
prejudiced in any way.
The responsibility to ensure compliance with the manual is vested in the
Development Committee which is a body selected by the BREHOA. The prime
responsibility of this body is to control the approval of building plans and to establish
whether the homes have been built in accordance with the approved plans.
The BREHOA has appointed In-line Architecture to advise and make
recommendations to the Committee as to whether plans submitted by owners
comply with the Architectural Guideline.
Scrutiny Fees The fee is based on a time base fee for a principal, with more than 10 years
experience, of an architect’s practice, as recommended by the South African
Council for the Architectural Profession.
Current fee (as per Board Notice 471 of 2023) is R 2 531.00 excluding VAT / hour x 2
hours.
Submission Formats 1) Sketch Plans
a) Client and Architects full contact detail,
b) Drawings are to be submitted in .pdf format per e-mail.
Drawings are to include:
Ground floor layouts,
First floor,
Elevations,
Sections
Sewer layout plan and
Site layout.
16
2) Municipality Plans
Municipality plans must show the following information
Information as required as per the Nasional Building Regulation,
The position of existing neighbouring houses
Sections must clearly indicate the flood level 1:64, average natural ground
line and building heights to the roof ridge.
Turnaround Times All plans (sketch and municipal) will be scrutinised and returned to the Client within 5
working days.
The plans will be returned with notes, the BREHOA stamp and letter of approval
(where applicable).
Submissions must be to the Development Committee’s nominated architectural
professional.
No drawings may be submitted to the local authority for approval until it has been
certified as approved by the BREHOA.
31
BUILDING OPERATIONS CONTROL
See the Belle Rio Estate Homeowners Association, Contractors Code of Conduct
Annexure A
17